The effect of hydrostatic pressure on invasive measures of coronary physiology

thesis
posted on 2023-08-30, 19:07 authored by Firas Al-Janabi
Introduction: Coronary arteries are at differing vertical heights in a supine patient relative to the aortic root. Pressure within an artery varies based on distance from the aorta due to hydrostatic effect. This could impact pressure-based indices of stenosis severity, as the vertical distance between distal and proximal pressure sensors creates a baseline pressure difference. This is neglected in clinical practice, as distal and proximal sensors are considered at the same vertical level. Methods: Pd/Pa, instantaneous wave free ratio (iFR), fractional flow reserve FFR and doppler flow velocity were recorded in 23 coronary stenoses in the standard supine patient position, and in the prone position. Measurements between positions were compared using a Student’s t test for matched pairs. Results: There were significant differences in mean Pd/Pa (0.05), iFR (0.06) and FFR (0.06) when comparing prone and supine positioning (p<0.05). When inferior to the aorta, mean Pd/Pa, iFR and FFR were 0.96±0.05, 0.93±0.11 and 0.84±0.10 respectively. When superior, mean Pd/Pa, iFR and FFR were 0.91±0.07, 0.87±0.11 and 0.78±0 respectively. Resting and hyperaemic doppler flow measurements did not change significantly when comparing prone and supine patient position. 26% of all FFR and 36% of all iFR values were re-classified across a treatment threshold when hydrostatic effect was corrected. Conclusion. Patient position alters physiological stenosis severity as quantified by invasive coronary pressure measurements. Coronary stenoses positioned inferiorly to the aorta, produce significantly higher Pd/Pa, iFR and FFR values when compared to a superior position. Conversely, patient position did not influence coronary doppler flow velocity. This is the first study to quantify the effect of hydrostatic pressure on invasive measures of coronary stenosis. The data supports hydrostatic effect as a potential confounding factor leading to inaccurate lesion assessment.

History

Institution

Anglia Ruskin University

File version

  • Accepted version

Language

  • eng

Thesis name

  • Other

Thesis type

  • Doctoral

Legacy posted date

2021-09-30

Legacy creation date

2021-09-30

Legacy Faculty/School/Department

Theses from Anglia Ruskin University/Faculty of Health, Education, Medicine and Social Care

Note

Accessibility note: If you require a more accessible version of this thesis, please contact us at arro@aru.ac.uk

Usage metrics

    ARU Theses

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC